Masonry Grout Volume
0.659 m³

48 pre-mixed bags (14 L/bag) or 0.86 cu yd

Net Core Fill Volume (Exact)
0.599 m³ (599 L)
With Waste Allowance (Purchase Qty)
0.659 m³ (658.9 L)
Estimated Bags (Purchase Qty)
48 bags
Estimated Cost (Estimated Cost)
$480.00

Planning note: Estimates execute locally in your browser. Always confirm package yields and site tolerances before ordering; not a substitute for structural engineering.

How This Calculator Works

Multiplies block core cavity dimensions by filled cores per block and total blocks to output cubic meters, cubic yards, and bag counts.

When to Use It

  • Estimating coarse or fine masonry grout to fill hollow CMU cells around vertical bars.

Required Measurements

  • Block count, filled cores per block, internal core L×W×H, and bag yield in liters.

Mathematical Formulas

Core Fill Volume

Volume = Blocks × CoresPerBlock × (CoreL × CoreW × CoreH) × (1 + Waste%)

CoresPerBlock:
Number of hollow cells filled per block

Worked Example: 100 Blocks × 2 Cores (130×120×190 mm)

10% waste, 13 L bag yield.

Example Inputs

  • 100 blocks
  • 2 cores/block
  • 130×120×190 mm
  • 10% waste

Step-by-Step Math

  1. Single core = 2.964 L; 200 cores = 592.8 L.
  2. With 10% = 652.08 L -> ceil(652.08 / 13) = 51 bags.

Result: 0.652 m³ (51 bags of 13 L yield).

Understanding Your Results

Exact Mathematical Output
Direct geometric or physical quantity computed from your entered dimensions before rounding.
Recommended Purchase Quantity
Whole bags, boxes, sheets, or units rounded upward so your order covers the waste-adjusted target.
Estimated Cost
Calculated strictly from your entered unit price without assumed market rates.

Assumptions

  • Uniform rectangular approximation of tapered block cells.

Common Calculation Mistakes

  • Counting all cores when only reinforced cells every 32 or 48 inches are grouted.

Scope, Safety Boundaries & Limitations

Safety boundary: Volume estimation only; follow structural drawings for which cells require grout and rebar.

  • Does not specify rebar size, lap splice length, or structural grout strength.
Formula & Unit References: NIST / ISO 80000-3 International Unit Definitions — Exact SI length, mass, and volume conversion factors (0.3048 m/ft, 0.45359237 kg/lb, 3.785411784 L/US gal)

Frequently Asked Questions

How much grout does a standard 8×8×16 CMU block hold?

Two cores of a standard 8-inch block typically hold roughly 0.16–0.21 cu ft (4.5–6.0 liters) total.